The high-low temperature pulse pressure test bench is primarily used for conducting static pressure, burst, leakage, fatigue, thermal cycling, and pressure pulse tests on components that are not designed to withstand high pressure.

    Product Description

    The high-and-low-temperature pulse pressure test bench is primarily designed for testing components that are not pressure-resistant. It performs static pressure, burst, leakage, fatigue, thermal cycling, and pressure pulse tests. The test bench allows for the configuration of test parameters and customer information; it provides real-time displays of pressure-versus-time curves, ambient/medium temperatures, pulse counts, and pressure values, with options for printing test data.

     

    Standards

    GB/T 18948-2017: Specification for rubber hoses and tubing for internal combustion engine cooling systems

    GB 16897-2022: Brake hoses — Structure, performance requirements, and test methods

    QC/T 468-2010: Automotive radiators

    DIN 73411-2:1996: Cooling system hoses and assemblies for automotive vehicles — Part 2: Requirements and tests

    TL 52361, GMW 14329, GMW 15904, GMW 14785, GMW 16295, GM 6278, etc.

    Technical parameters

    Name Project Main technical parameters
    Hydraulic control system Medium system Test medium PAG oil (users need to provide)
    Medium temperature -40~150℃
    Heating rate 0~3°℃/min (average over the whole process, nonlinear), load 3KM heating power and thermal power
    Heating rate 0~2℃/min (average over the whole process, nonlinear), load 3KW heating power and thermal power
    Medium heating method Closed indirect heating to avoid high temperature carbonization of the test medium
    Exhaust system Independent automatic exhaust system
    Exhaust method Side inlet and side outlet
    Electro-hydraulic servo pulse system Pulse generator Servo supercharger
    Test product C02 air conditioning pipe
    Test pressure 0~17MPa
    Pulse frequency 0~3Hz can be set arbitrarily (the larger the expansion volume, the smaller the pulse pressure range)
    Pulse time Can be set arbitrarily
    Number of test paths 2~10 channels
    Total expansion of the specimen ≤250mL (the larger the frequency, the smaller the expansion volume requirement)
    Other 1. The main oil tank and medium tank should be designed with a liquid level alarm. When the liquid level reaches the lower limit, the whole machine cannot be started.
    2. The main oil tank and medium tank have an over-temperature alarm and shutdown function.
    3. The test system is equipped with an exhaust device to effectively remove the gas in the test piece.
    High and low temperature environmental chamber Ambient temperature control system Temperature range -40C~150℃
    Temperature deviation ±2℃(no load)
    Heating rate (customizable) 0~2℃/min, with a certain mass load, linear or nonlinear temperature rise
    Cooling rate (customizable) 0~2℃/min, with a certain mass load, linear or nonlinear temperature rise
    Connection tooling Side-in and side-out structure, aluminum profile frame, easy to adjust, connecting tooling can achieve horizontal and vertical adjustment; horizontal adjustment range (400-1400mm), vertical adjustment range (200-700mm)
    Safety door Single door on the front, with coated heating and anti-frost hollow double-layer tempered glass observation window on the door; two fluororubber sealing strips and anti-condensation electric heating device on the door frame, with door limit and door opening stop function
    Lighting Safety door observation window is equipped with lighting
    Computer control system 1. Waveform control: Using FPID electro-hydraulic control technology, the pulse pressure waveform, pulse number, static pressure time, medium temperature, and pulse frequency can be set arbitrarily within the controllable range, and the pressure measurement accuracy can be improved.
    2. Pulse waveform: trapezoidal wave, sine wave, triangle wave
    3. Others
    (1) It has the functions of oil temperature over-high, pressure over-high, leakage sound and light alarm, and emergency shutdown
    (2) The alarm point can be set for test piece leakage. When the leakage reaches a certain level, the system will automatically alarm and stop working
    (3) The test system should provide corresponding equipment calibration conditions (such as pressure sensor calibration interface or calibration procedure)
    PC Lower computer PLC+NI card
    Upper computer Touch screen computer
    Software Control software Pulse control software (developed by LabVIEW)
    Report format Microsoft Office