Leave Your Message
Formaldehyde Emission Assessment Scheme For Automotive Interior Parts
Technical Article

Formaldehyde Emission Assessment Scheme For Automotive Interior Parts

2026-09-04
15

I. Background and Basis of the Solution

As a core interior component, the automotive dashboard assembly is exposed to high-temperature, enclosed environments for extended periods, and its formaldehyde emission directly impacts in-vehicle air quality. This solution is implemented in accordance with GB/T 27630-2011 "Guidelines for Evaluating Air Quality in Passenger Cars" and VDA275 "Standard for Testing Formaldehyde Emission from Automotive Interior Materials".

微信图片_2026-09-04_102846_187.png

II. Specific Experimental Parameters

Parameter Items Set Values
Test Chamber Volume 1m³±0.02m³
Chamber Temperature 65℃±1℃ (simulating summer sun exposure)
Chamber Relative Humidity 50%±5%RH
Air Exchange Rate 1.0 times/hour
Sample Surface Area 100cm² (cut into 40mm×100mm dimensions)
Sampling Time 3 hours (static adsorption)
Formaldehyde Background Concentration ≤0.006mg/m³

The testing equipment used is a professional-grade environmental chamber provided by the formaldehyde VOC Environmental Testing Chamber manufacturer to ensure that the background cleanliness meets the testing requirements.

III. Experimental Procedure

Step 1: Sample Pretreatment Cut the instrument panel assembly sample into standard 40mm × 100mm pieces, weigh and record the weight, then suspend them in the test chamber, maintaining a 40mm gap between the lower edge of the sample and the water surface.

Step 2: Chamber Equilibration Run the test chamber at 65℃ and 50%RH for 2 hours. After the temperature and humidity stabilize, place the sample inside and seal the chamber door to begin testing.

Step 3: Gas Sampling After 3 hours, collect the gas inside the chamber using a sampling pump at a flow rate of 0.5L/min. Introduce the gas into an absorption bottle containing acetylacetone solution for derivatization reaction.

Step 4: Analysis and Detection Measure the absorbance at a wavelength of 412nm using a spectrophotometer. Substitute the absorbance into a standard curve to calculate the formaldehyde concentration.

IV. Experimental Results Data

Test Indicators Measured Values Standard Limits (GB/T 27630) Judgment
Formaldehyde Emission 0.082 mg/m³ 0.10 mg/m³ Pass
Acetaldehyde Emission 0.031 mg/m³ 0.05 mg/m³ Pass
TVOC Emission 0.48 mg/m³ 0.60 mg/m³ Pass

In this test, the formaldehyde emission from the dashboard assembly was 0.082 mg/m³, which is lower than the national standard limit of 0.10 mg/m³.

V. Conclusion

An accelerated formaldehyde release test was conducted on the automotive dashboard assembly using a 1m³ formaldehyde VOC environmental testing chamber at 65℃ and 50%RH for 3 hours. The results showed that the formaldehyde release of the sample met the requirements of GB/T 27630-2011 standard. The formaldehyde VOC environmental testing chamber equipment mentioned in this article can be widely used for formaldehyde assessment of automotive interior components such as seats, carpets, and headliners.